Nortel Communication Server 1000 Manual page 147

Dass2 fundamentals
Hide thumbs Also See for Communication Server 1000:
Table of Contents

Advertisement

Table 72
Steps for installing the NT8D72 PRI card (cont'd.)
Step
Action
6
If required, install I/O adapters in I/O panel.
7
Run and connect the PRI cables.
8
If required, install connecting blocks at MDF or wall mounted cross-connect
terminal.
9
If required, designate connecting blocks at MDF or wall mounted cross-connect
terminal.
10
If required, install Network Channel Terminating Equipment (NCTE).
11
Cross-connect PRI circuits.
12
Add related office data into switch memory.
13
Run IDA status check. Refer to the DASS2 (NN43001-571) for the IDA verification
tests, IDA status check, and IDA startup test.
Installing a system network expansion shelf
The procedure in
(page 147)
"Integrated Digital Access (IDA) equipment" (page 77)
representation of a Meridian 1 network expansion shelf"
Table 73
Steps for installing a network expansion shelf
Action
Step
1
Determine the cabinet and shelf location of the Network shelf to be installed.
2
Unpack and inspect the shelf.
3
Remove the existing left or right rear Intelligent Peripheral Equipment (IPE) shelf
(if required).
4
Install the additional Network shelf in the IPE (Step 3) location.
5
Install a QUD15 cooling unit directly below the Network shelf and secure with four
mounting screws.
Table 73 "Steps for installing a network expansion shelf"
is used schematic representation of a network expansion shelf.
CAUTION
Service Interruption
Do not place the circuit cards in the shelf until Step 7 is
completed.
Nortel Communication Server 1000
DASS2 Fundamentals
NN43001-571 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Non DPRI 147