120 Integrated Digital Access (IDA) equipment
NT5K86CA wire list
Table 54 "NT5K86CA wire list" (page 120)
NT5K86CA cable.
Table 54
NT5K86CA wire list
Signal
XTIP (transmit)
XRING (transmit)
RTIP (receive)
RRING (receive)
FRAME GROUND
QCAD328A
The NT5K35, NT5K75 and NT6D11AE D-channel interface connects to
the NT8D72 PRI by means of the QCAD328A, which is a special RS422
cable. This cable has the following attributes:
Construction - 24 AWG (0.511 mm), stranded
P1 Connector (from DCHI) - 25-pin male, subminiature D
P2 Connector (to PRI) - 15-pin male, subminiature D
QCAD328A wire list
Table 55 "QCAD328A wire list" (page 120)
QCAD328 cable.
Table 55
QCAD328A wire list
From DCHI (25 Pin)
P1-2
P1-13
P1-20
P1-15
P1-14
P1-3
P1-16
P1-17
P1-12
P1-8
From (card end)
J1-1
J1-9
J1-3
J1-11
J1-2
Nortel Communication Server 1000
DASS2 Fundamentals
NN43001-571 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
provides a wire list for the
To (I/O end)
J2 Inner Conductor
J2 Shield
J3 Inner Conductor
J3 Shield
J2 Shield, J3 Shield
provides a wire list for the
To PRI (15 Pin)
P2-2
P2-10
P2-15
P2-9
P2-11
P2-4
P2-12
P2-5
P2-13
P2-8