172 IDA status check and start-up

IDA status check

This status check outlined in
used to verify that an IDA link is working normally. It assumes the PRI and
DCHI are properly installed (for example, correctly cabled) and operational.
If the IDA status is not as shown in the steps below, complete the check
and proceed to IDA fault clearing procedures.
Once all problems are cleared, go to IDA start-up.
Table 92
IDA status check
Action
Step
1
Check the status LEDs on PRI cards.
2
Note whether any other LED is lit and
continue with the status check.
3
Check the LED on the DCHI faceplate.
4
Check the status of all DCHI ports using:
LD 75
STAT DDSL
5
Check the status of PRIs using:
LD 75
STAT DDCS
STAT DDCS n