Planet GS-5220 Series User Manual page 517

L2+ gigabit/10 managed lcd switch
Hide thumbs Also See for GS-5220 Series:
Table of Contents

Advertisement

• Sample Type
• Value
• Startup Alarm
• Rising Threshold
• Rising Index
• Falling Threshold
• Falling Index
Buttons
: Click to add a new community entry.
: Click to apply changes
:
Click to undo any changes made locally and revert to previously saved values.
The method of sampling the selected variable and calculating the value
to be compared against the thresholds; possible sample types are:
Absolute: Get the sample directly.
Delta: Calculate the difference between samples (default).
The value of the statistic during the last sampling period.
The method of sampling the selected variable and calculating the value
to be compared against the thresholds; possible sample types are:
RisingTrigger alarm when the first value is larger than the rising
threshold.
FallingTrigger alarm when the first value is less than the falling
threshold.
RisingOrFallingTrigger alarm when the first value is larger than the
rising threshold or less than the falling threshold (default).
Rising threshold value (-2147483648-2147483647).
Rising event index (1-65535).
Falling threshold value (-2147483648-2147483647)
Falling event index (1-65535).
517