General Settings
Object
Enable Loop
Protection
• Transmission Time
Shutdown Time
Port Configuration
Object
Port
• Enable
• Action
Tx Mode
Buttons
: Click to apply changes
:
Click to undo any changes made locally and revert to previously saved values.
Description
Controls whether loop protection is enabled (as a whole).
The interval between each loop protection PDU sent on each port.
Valid values are 1 to 10 seconds.
The period (in seconds) for which a port will be kept disabled in the
event of a loop is detected (and the port action shuts down the port).
Valid values are 0 to 604800 seconds (7 days). A value of zero will keep
a port disabled (until next device restart).
Description
The switch port number of the port.
Controls whether loop protection is enabled on this switch port.
Configures the action performed when a loop is detected on a port.
Valid values are Shutdown Port, Shutdown Port and Log or Log Only.
Controls whether the port is actively generating loop protection PDU's,
or whether it is just passively looking for looped PDU's.