• TCP URG
Ethernet Type Parameters
The Ethernet Type parameters can be configured when Frame Type "Ethernet Type" is selected.
Object
EtherType Filter
•
Ethernet Type Value
•
Buttons
Specify the TCP "Urgent Pointer field significant" (URG) value for this
ACE.
0: TCP frames where the URG field is set must not be able to
■
match this entry.
1: TCP frames where the URG field is set must be able to match
■
this entry.
Any: Any value is allowed ("don't-care").
■
Description
Specify the Ethernet type filter for this ACE.
Any: No EtherType filter is specified (EtherType filter status
■
is "don't-care").
Specific: If you want to filter a specific EtherType filter with
■
this ACE, you can enter a specific EtherType value. A field for
entering a EtherType value appears.
When "Specific" is selected for the EtherType filter, you can enter a
specific EtherType value.
The allowed range is 0x600 to 0xFFFF but excluding 0x800(IPv4),
0x806(ARP) and 0x86DD(IPv6). A frame that hits this ACE matches this
EtherType value.
354