Managing OmniSwitch 6450 Stacks

Synchronizing Switches in a Stack

Management module synchronization refers to the process of copying all files in the /flash/working and
/flash/certified directories of the primary management module to the /flash/working and /flash/certified
directories of all the other switches in the stack. The system and configuration software on the non-
primary switches—i.e., the secondary management module and any modules operating in idle—is over-
written.
The synchronization process ensures that the contents of these directories match exactly for all switches
across the stack. This can be especially useful after new software has been loaded to the primary manage-
ment module. Further, synchronization prevents any switch from assuming a management role within the
stack with incorrect or outdated software or configuration files. Because the primary switch's "last known
good" software is propagated to all switches, the synchronization process helps ensure effective redun-
dancy across the stack.
In order to maintain effective management module redundancy, switches in the stack must be synchro-
nized at all times. To determine whether a stack is in need of synchronization, use the
directory
command. For example:
-> show running-configuration
CONFIGURATION STATUS
Running CMM
CMM Mode
Current CMM Slot
Running configuration
Certify/Restore Status
SYNCHRONIZATION STATUS
Running Configuration
This example shows a switch on which the /flash directories between the management modules are not
synchronized. To manually synchronize all switches in the stack, enter the following command:
-> copy working certified flash-syncro
When the synchronization process is initiated, modules within the stack continue to operate without inter-
ruption and data flow across the stack is unaffected.

Automatic Synchronization During a Full Reload

If the checksum value on the stack's non-primary switches differs in any way from the checksum value on
the primary switch, the primary switch automatically distributes its system and configuration software to
all other switches in the stack whenever a full reload is executed.
For more information on initiating a full reload, see
Note. For more information on management module synchronization and managing the /flash/working
and /flash/certified directories, refer to the "Managing CMM Directory Content" chapter in the OmniS-
witch 6250/6450 Switch Management Guide.
OmniSwitch 6450 Hardware Users Guide
: PRIMARY,
: MONO CMM,
: 1,
: CERTIFIED,
: CERTIFY NEEDED
: NOT SYNCHRONIZED,
"Reloading All Switches in a Stack" on page
January 2015
Synchronizing Switches in a Stack
show running-
5-32.
page 5-37

Advertisement

Table of Contents
loading

Table of Contents