Special Mention - Panasonic FPG Series Technical Manual

Positioning unit
Table of Contents

Advertisement

Home Return
FP2 Positioning Unit

10.9 Special Mention

The time from the home input to the pulse output stop during the home return (home
search)
The FP∑Positioning unit performs the process in the very high speed, so that it starts counting the
number of the output pulses within 1µs from when the home input is ON. The time is always stable,
enabling the accurate home return (home search) operation. Since each axis is completely independent,
the home returns by the multiple axes at the same time are possible for the multiple-axis type.