1.3 Restrictions on Units Combination

1.3.1 Restrictions on Combinations Based on Current Consumption

The internal current consumption (at 5 V DC power supply) for the positioning units is noted below.
When the system is configured, the other units being used should be taken into consideration, and a
power supply unit with a sufficient capacity should be used.
Part number
FPG-PP11
FPG-PP21
FPG-PP12
FPG-PP22

1.3.2 Restrictions on Unit Installation Position

Up to 4 of the positioning units can be installed to the left of the FP∑ Control Unit. (Installing to the right
is unavailable.)

1.3.3 Restrictions on the Number of Units Installed

There are no restrictions on the number of units that may be installed, as long as the restrictions
described in 1.3.1 and 1.3.2 above are observed.
Product number
AFPG430
AFPG431
AFPG432
AFPG433
Fanctions of FPΣ Positioning Unit
Current consumption at 5 V DC
150mA
220mA
150mA
220mA
1-7