10.7 Operation at Over limit Input

Home return operation is as follows when Over limit input (+) or Over limit input (-) is ON.
The operation in the direction in opposite to the input limit is possible.
Home Return (without home search)
Condition
When Home return is
turned ON
During Home return
operation
Home Return (with home search)
Condition
When Home return is
turned ON
During Home return
operation
10-24
Direction
Forward
Reverse
Forward
Reverse
Direction
Forward
Reverse
Forward
Reverse
Limit status
Over limit input
(+):ON
Over limit input
(-):ON
Over limit input
(+):ON
Over limit input
(-):ON
Over limit input
(+):ON
Over limit input
(-):ON
Limit status
Over limit input
(+):ON
Over limit input
(-):ON
Over limit input
(+):ON
Over limit input
(-):ON
Over limit input
(+):ON
Over limit input
(-):ON
FP2 Positioning Unit
Operation
Table not to move,
Limit error occurs.
Table to move
Table to move
Table not to move,
Limit error occurs.
Table stops,
Limit error occurs.
Table stops,
Limit error occurs.
Operation
Table to move
Table to move
Table to move
Table to move
Automatic-reverse
operation
Automatic-reverse
operation