8.6 Operation at Over limit Input

JOG operation is as follows when Over limit input (+) and Over limit input (-) is ON .
The operation is possible for the direction in opposite of the input limit.
Condition
When JOG operation is
turned ON
During JOG operation
Direction
Limit status
Over limit input(+):ON
Forward
Over limit input (-):ON
Over limit input (+):ON
Reverse
Over limit input (-):ON
Forward
Over limit input (+):ON
Reverse
Over limit input (-):ON
Operation
Table not to move, Limit error occurs.
Table to move.
Table to move.
Table not to move, Limit error occurs.
Table stops, Limit error occurs.
Table stops, Limit error occurs.
JOG Operation