4.2 Conversion of Special Relays

When using special relays on a conventional model, address conversion is performed in
accordance with the conversion rule for converting programs to FP7.
 Conversion rule
(1) Only for convertible special relays, address conversion is performed.
(2) As only similar device items are converted, the device addresses after R902C cannot be
converted.
(3) Word accesses (from WR900) cannot be converted.
 Operation when an instruction cannot be converted
Converts instructions leaving inconvertible device numbers unchanged, and sets "network to
be excluded from execution".
Example) Before converting an FP2SH program
Example) After converting the program to FP7 program
In the above example, the device addresses R9001 to R9003, and R9005 are the output
results of inconvertible items.
List of convertible special relays
Convertible special relays are as follows.
All other special relays cannot be converted.
FP2SH
Device
Name
R9000
Self-diagnosis error occurrence
R9004
I/O verification error flag
R9007
Operation error detection (Hold)
R9008
Operation error detection (Latest)
R9009
CY
R900A
>
R900B
=
R900C
>
R900D
Auxiliary timer contact
R900F
Constant scan error flag
R9010
Always ON
R9011
Always OFF
R9012
Scan relay
R9013
1st scan ON
R9014
1st scan OFF
R9015
Step ladder initial ON
4.2 Conversion of Special Relays
FP7
Device
Name
SR0
Self-diagnosis error occurrence
SR4
Unit verify error occurrence
SR7
Operation error detection (Hold)
SR8
Operation error detection (Latest)
SR9
CY
SRA
>
SRB
=
SRC
>
SRD
Auxiliary timer contact
SRF
Constant scan error flag
SR10
Always ON
SR11
Always OFF
SR12
Scan relay
SR13
1st scan ON
SR14
1st scan OFF
SR15
Step ladder initial ON