7.2 Operation at Over Limit Input

7.2 Operation at Over Limit Input

Operation at over limit input
Operations depend on the status of over limit input (+) and over limit input (-) as follows.
Condition
When P-point control is
started
While P-point control is
being performed
Input valid logic of over limit input
● When the over limit switches (+) (-) are not connected to the pulse output unit, change the
input valid logic of the over limit switch to "NO contact". The default is "NC contact", and an
over limit error occurs.
7-8
Direction
Forward
Reverse
Forward
Reverse
Limit status
Over limit input (+): ON
Over limit input (-): ON
Over limit input (+): ON
Over limit input (-): ON
Over limit input (+): ON
Over limit input (-): ON
Over limit input (+): ON
Over limit input (-): ON
Operation
Not executable, Error
occurs.
Not executable, Error
occurs.
Not executable, Error
occurs.
Not executable, Error
occurs.
Stop, Error occurs.
Stop, Error occurs.
Stop, Error occurs.
Stop, Error occurs.