Kyocera Copystar CS 3011i Service Manual page 556

Table of Contents

Advertisement

Number
Contents
F34X
Abnormality detecting in the Panel Manage-
ment Department
F35X
Abnormality detecting in the printing controlling
Management Department
F37X
Abnormality detecting in the FAX Management
Department
F38X
Abnormality detecting in the authentication
authorized Management Department
F3AX
Abnormality detecting in the Entity Manage-
F3BX
ment Department
F3CX
F3DX
F3EX
F3FX
F40X
F41X
F42X
F43X
F44X
F45X
Verification procedure & check point
1. Check the harness between Panel<=>Main boards, and the connection state of a connec-
tor, and perform an operation check.
2. Initialize HDD and perform an operation check.
(FULL of U024) *
3. U021 Controller backup initialization is carried out and an operation check is performed.
4. Exchange a Panel board and perform an operation check.
5. Exchange a Main board and perform an operation check.
6. Get USBLOG and contact service headquarters.
* Only HDD standard model
1. Initialize HDD and perform an operation check.
(FULL of U024) *
2. Carry out U021 Main backup initialization and perform an operation check.
3. Exchange a Main board and perform an operation check.
4. Exchange HDD and perform an operation check.
*
5. Get USBLOG and contact service headquarters.
* Only HDD standard model
1. Initialize HDD and perform an operation check.
(FULL of U024) *
2. Carry out U021 Main backup initialization and perform an operation check.
3. Perform a deed operation check for DIMM Clear by U671.
(Since it disappears when received data remain, cautions are required.) * notes
4. Exchange FAX_DIMM and perform an operation check.
* Notes
5. Exchange a Main board and perform an operation check.
6. Exchange HDD and perform an operation check.
*
7. Get USBLOG and contact service headquarters.
* Only HDD standard model
* Note Only model which has Flash for FAX data in a Main board
1. Initialize HDD and perform an operation check.
(FULL of U024) *
2. Carry out U021 Main backup initialization and perform an operation check.
3. Exchange a Main board and perform an operation check.
4. Exchange HDD and perform an operation check.
*
5. Get USBLOG and contact service headquarters.
* Only HDD standard model
1. Initialize HDD and perform an operation check.
(FULL of U024) *
2. Carry out U021 Main backup initialization and perform an operation check.
3. Exchange a Main board and perform an operation check.
4. Exchange HDD and perform an operation check.
*
5. Get USBLOG and contact service headquarters.
* Only HDD standard model
2-4-21
Remarks
Content
[Main <=> Panel]
Main PWB: YC12
Panel PWB: YC5
No Flash for FAX data
When OFF of the security kit that
replaced the HDD to the SSD.
2RG/2RH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Copystar cs 3511i