9. Wind the outer scanner wires from above to below on the outside grooves in the pulleys at the secondary
mirror frame. ..............(1)
10. Hook the round terminals to the catches inside the scanner unit. ..............(2)
11. Wind the inner scanner wires from below to above in the grooves of left side scanner unit. ..............(3)
12. Wind from below to above inside grooves of the secondary mirror frame pulley. ..............(4)
13. Wind the scanner wires around the grooves in the pulleys at the left of the scanner unit ..............(5)
14. Hook the round terminals to the scanner wire springs. ..............(6)
15. Remove the two scanner wire stoppers
and the mirror frame securing tools.
16. Move to center the portion of the locat-
ing ball in the scanner wire drum, and
the scanner wires to inside.
17. Move the mirror frame 2 from side to
side in order to correctly locate the
wires in position.
18. Refit the mirror frame 1.
19. Move the mirror frame 1 and 2 to the left
side of the machine, and insert the two
frame securing tools into the positioning
holes at the front and rear of the scan-
ner unit to secure the frames in posi-
tion.
20. Hold the wires and fix each front and
rear wire holder plate to the mirror
frame 1 with the screw.
21. Remove the two frame securing tools.
22. Refit all the removed parts.
Black merking
Gray
Frame securing tool
1-5-53
Black
Figure 1-5-91
Frame securing tool
Mirror frame 2
Mirror frame 1
Figure 1-5-92
2RG/2RH