Kyocera Copystar CS 3011i Service Manual page 321

Table of Contents

Advertisement

Code
Contents
3210
CIS lamp error
When input value at the time
of CIS illumination does not
exceed the threshold value
between 5 s.
3300
Optical system (AGC) error
When the value of a gain
becomes more than FF or 89
or less at least one at the
AGC processing instruction
execution time for CCD
lamps.
Related parts
CIS
DPSHD PWB
Replace the DPSHD PWB.
DP relay PWB
Replace the DP relay PWB.
LED lamp PWB
CCD PWB
Replace the ISU and execute U411 (see
page 1-5-34).
Engine PWB
Replace the Engine PWB and execute U411
(see page 1-5-59,1-3-130).
Main PWB
Replace the main PWB (see page 1-5-54).
1-4-28
Check procedures/
corrective measures
1. Execute U906 Separating Operation
Release (see page 1-3-191).
2. Execute CIS of U061 lamp check (see
page 1-3-43).
3. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
CIS and DPSHD PWB (YC2)
DPSHD PWB (YC3) and DP relay PWB
(YC2)
4. If the wiring is disconnected, shorted or
grounded, replace the wiring.
5. Replace the CIS and execute U091 and
U411 (see page 1-3-58,1-3-130).
1. To check the lamp, execute U061 CCD
(see page 1-3-43).
2. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
LED lamp PWB and CCD PWB (YC2)
CCD PWB (YC1) and Engine PWB
(YC29)
Engine PWB (YC3) and Main PWB
(YC64)
3. If the wiring is disconnected, shorted or
grounded, replace the wiring.
4. If the LED lamp won't light, replace the
LED PWB and execut U411 (see page
1-3-130).
2RG/2RH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Copystar cs 3511i

Table of Contents