Diagnostics Using 'Blink Codes; Blink Codes - Operation - Polaris Ranger 500 2x4 2007 Service Manual

Electronic fuel injection
Table of Contents

Advertisement

DIAGNOSTICS USING 'BLINK CODES'

Blink Codes - Operation

To enable the blink codes:
1. Turn the ignition from 'OFF' to 'ON' 3 times, leaving it 'ON'
the 3rd time, within 5 seconds.
2. The blink codes appear when the Orange MIL light blinks in
sequence:
• Count the number of times the Orange MIL light flashes.
• The blink codes are double digit numbers.
• The first digit of the double digit number will flash first, then
a pause and the second digit number will flash.
• Example: For a Code 42 -- The Orange MIL light will flash 4
times, pause, then flash 2 times.
• A code 61 will signal the end of the blink codes.
Malfunction Indicator Light (MIL) Diagnostic Example
ELECTRONIC FUEL INJECTION
• The Orange MIL light will then remain lit when finished.
3. When the diagnostic mode is complete, the Orange MIL light
will remain illuminated until the key is switched off.
NOTE: To clear codes manually, disconnect the
positive battery lead for 20 seconds.
Orange MIL Light
OFF
ON
4
Sequence Begin
Trouble Code
Trouble Code
Trouble Code
Sequence End
4.41

Advertisement

Table of Contents
loading

This manual is also suitable for: