Polaris Ranger 500 2x4 2007 Service Manual page 329

Electronic fuel injection
Table of Contents

Advertisement

Starter System Test Flow Chart, cont'd.
Test B (from previous page)
Voltage Drop Testing
Reconnect the solenoid. Connect the tester black
lead to the battery positive and the red lead to the
solenoid end and actuate the starter. Reading
should be less than .1 V D.C
.
Yes
Connect the black tester lead to solenoid end of
battery-to-solenoid cable. Connect red tester lead
to solenoid end of solenoid-to-starter cable.
Reading should be less than .1 V D.C.
Yes
Connect the black tester lead to the solenoid end
of the solenoid-to-starter cable. Connect the red
tester lead to the starter end of the same cable.
The reading should be less than .1 V D.C.
Yes
If all of these indicate a good condition, yet the starter still fails to turn, the starter
must be removed for static testing and inspection.
Continued from previous page
No
No
No
ELECTRICAL
Clean the battery-to-solenoid cable ends
or replace the cable.
Replace the starter solenoid.
Clean the solenoid-to-starter cable ends
or replace the cable.
10
10.43

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ranger 500 4x4 2007Ranger 500 4x4 efi 2007

Table of Contents