What to do if ... | Malfunctions
Fault
Control voltage is missing
Connection to the
network is not possible
The connected USB mass
storage device is not
detected
The unit starts in recovery
mode (text only mode)
User login is not possible
HEIDENHAIN | POSITIP 8000 | Operating Instructions Milling | 03/2020
Cause of fault
Correction of fault
External peripherals
Defective connection
Incorrect settings of
the network
Defective USB
connection
The type or format-
ting of the USB mass
storage device is not
supported
Firmware error during
startup
Password does not
exist
Conduct a systematic error
search
Check the cable and the
correct connection to X116
Check the network settings
Page 140
Check the correct position
of the USB mass storage
device in the port
Use another USB port
Use another USB mass
storage device
Format USB mass storage
device with FAT32
If this fault occurs for
the first time, switch the
product off and then on
again
If the fault recurs, contact
a HEIDENHAIN service
agency
As user with higher
permission level, reset the
password
Page 136
To reset the OEM
password, contact the
HEIDENHAIN service
agency
17
Personnel
Qualified
personnel,
possibly OEM
Qualified
personnel
Qualified
personnel
Qualified
personnel
Qualified
personnel
Qualified
personnel
Qualified
personnel
297