15
Parameter
Display mode
Mechanical ratio
Reference marks
Analog filter frequency
Terminating resistor
Error monitor
254
Explanation
For angle encoders and for the display of a rotary axis as a linear
axis.
Settings:
- ∞ ... ∞
0° ... 360°
-180° ... 180°
Default value: - ∞ ... ∞
For display of a rotary axis as a linear axis:
traverse path in mm per revolution
Setting range: 0.1 mm ... 1000 mm
Default value: 1.0
Configuration of the Reference marks
"Reference marks (Encoder)", Page 255
Further information:
Frequency value of the analog low-pass filter
Settings:
33 kHz: Suppression of interference frequencies above
33 kHz
400 kHz: Suppression of interference frequencies above
400 kHz
Default value: 400 kHz
Dummy load to avoid reflections
Settings: ON or OFF
Default value: ON
Monitoring of signal errors
Settings:
Off: Error monitoring not active
Amplitude: Error monitoring of the signal amplitude
Frequency: Error monitoring of the signal frequency
Frequency & amplitude: Error monitoring of the signal
amplitude and signal frequency
Default value: Frequency & amplitude
A warning or error message is displayed if one of the
limit values for error monitoring is exceeded.
The limit values depend on the signal of the connected encoder:
Signal 1 Vpp, setting: Amplitude
Warning with voltage ≤ 0.45 V
Error message with voltage ≤ 0.18 V or ≥ 1.34 V
Signal 1 Vpp, setting: Frequency
Error message with frequency ≥ 400 kHz
Signal 11 µApp, setting: Amplitude
Warning with current ≤ 5.76 µA
Error message with current ≤ 2.32 µA or ≥ 17 .27 µA
Signal 11 µApp, setting: Frequency
Error message with frequency ≥ 150 kHz