Install the three special low-profile M4 x 3.2mm Philips screws provided to secure the
inner rail to the chassis.
e. Follow these steps for the second inner rail on the opposite side of the enclosure.
Step 47 : Attach a cable tie mount to the cable tray.
a. Clean the surface of the cable tray, under the mounting area, with isopropyl alcohol and
allow to dry.
b. Adhere a cable tie mount in the approximate location shown in the following diagram:
Step 48 : Extend the mid-rails out of the rack so that they are protruding from the front of the rack and the
safety latches engage.
Figure 378: Slide Inner Rail
Caution: When installing the inner rail onto the chassis, make sure to only
use the special Low-Profile M4 x 3.2mm Philips screws provided in the
accessory kit with the CMA. These screws should be tightened to .90-1.12
Nm / 8-10 in-lbf using a # 2 Philips Screwdriver. These screws are specially
designed for this purpose. Using unapproved screws could cause damage
to the slides inside the rail.
Figure 379: Cable Tie Mount Location
4. Part Replacement
4.14 Chassis Replacement