Specification
Table 2: Electrical Specifications
Specification
Max Power Consumption
Typical Power Consumption
PSU Connector Type
Inrush Current Maximum (per
Typical Inrush Current (per PSU)
Caution: The Ultrastar Serv60+8 can only be plugged into high line (220-240 VAC). If the unit is
plugged into low line (110-127 VAC), the PSU will report a "Critical" state when status pages are
queried using SES. In this case, the enclosure will power up, but the drives will not.
Table 3: Mechanical Specifications
Specification
Enclosure Dimensions
Length of Enclosure w/
Required Rack Width
Required Rack Depth
Rack Units (U)
* Max and typical power consumption values represent the output power to the system. Input power will vary depending
on the PSU efficiency and load sharing between PSUs.
Non-Operational
Altitude
-300m to 12,000m /
-984 ft. to 39,370 ft
 *
Input Voltage
PSU Efficiency
PSU)
Non-Operational
Shock
10G, 0 - peak,11ms half sine;
3 positive and 3 negative
pulses in each axis shock
Vibration
0.75G, 0 - peak swept sine;
5 -500Hz; 1 complete sweep
@ 1/2 octave per minute
Weight
W: 447mm x L: 1030mm x H: 175mm / W: 17.6in. x L: 40.6in. x H: 6.89in.
CMA
450mm (17.72in.) minimum width with 465mm (18.31in.) ± 1.5mm nominal
hole spacing and W1 is 492mm minimum. See EIA-310 Rack Standard
1200 mm (47.24in.) of usable rack space, frame to frame
1.4 Ultrastar Serv60+8 Specification Summary
Value
~2000W
~1800W
200 - 240 VAC
C14
80 PLUS Platinum
AC line inrush current shall not exceed 35A peak
measured per IPC-9592B(L) Appendix C-4.1.
15A
5G, 0 - peak, 11ms half sine; 3 positive
and 3 negative pulses in each axis-
minimum 6 seconds between shocks
to allow for write/read recovery
0.10G,0 - peak swept sine; 5 -500Hz;
1 complete sweep @ 1/2octave per
minute
95.25 kg / 210 lbs.
CMA Standard: 1182mm / 46.5in.
CMA Lite: 1148mm / 45.2in.
4U
1. Overview
Operational
-300m to 3048m /
-984 ft. to 10,000 ft.
Operational
6