ELECTRICAL
GENERATOR
SERVICE DATA.
BENCH TESTING
Operation Tests.
Heating Test
, .
Ohmic Resistance Test.
Mechanical Characteristics Check Data
SERVICE PROCEDURES
.
SERVICE
DATA
Type
.
Nominal voltage
.
Continuous peak amperage (anuneter limit) .
Temporary peak amperage
Continuous peak wattage
Temporary peak wattage
Cut-in speed (12
V
at 68'
F -
20' C)
Speed for maximum continuous amperage (16 at 68
0
F - 200 C)
Speed for maximum peak amperage (22 at 680 F -
200
C)
Maximum speed, steady. . .
Rotation direction (drive end)
Pole shoes . . . .
Field winding. . .
Regulator. separate
Engine-to-generator drive ratio (new belt)
Pole shoe inner diameter
Brush Part No.
. . . . . . . . . . . . .
Bench Testing Data.
Testing generator as a motor (at 680 F -
200
C) ;
Feed voltage
Current draw
Speed . . . .
Output lest (at 68'
F -
20' C) :
Steady voltage . . . . . . . . . . . . .
Speed for abt. I hour and 45 min. . . .
Current delivery to resistor (at 14 Volts)
(->
New drive ratio from engine No. &19463: 2 to 1.
199
page
199
»
201
»
201
»
202
»
202
»
202
»
203
D 90/12/16/3 CS
12
16
22
230
320
1,710 to 1,790 r.p.m.
2,550 to 2,700 r.p.m.
3,OSO to 3,200 r.p.m.
9,000 r.p.m.
counterclockwise
2
shunted
FIAT GN 2/12/16
1.8
to
I (')
2.295" to 2.301" (58.3 to 58.4S mm)
4110BSI or 4110BS2
12
4.5 to 5.5 Amps
1,400 to 1,600 r.p.m.
12
4,500
r.p.m.
15,5 \0 16.5 Amps