Jnp10K-Pwr-Ac Power Specifications - Juniper MX10016 Hardware Manual

Universal routing platform
Hide thumbs Also See for MX10016:
Table of Contents

Advertisement

NOTE:
The HVAC/HVDC power supply, JNP10K-PWR-AC2, has a set of dip switches on the
faceplate that allows you to configure the power supply for either high power (30 A) or low
power (20 A) input mode. If any JNP10K-PWR-AC2. power supply is set to 20 A, then the power
budget for all power supplies installed in the system becomes 20 A, regardless if other power
supplies are set at 30 A. This design is to prevent overloading of the power supply that is set
to 20 A. See Power Input and Output Voltages for JNP10K-PWR-AC2 Power Supplies for details
on setting the dip switches.
2. Determine the total power required for your configuration with line cards installed. The total power
available to the chassis is calculated by dividing the wattage needed by the power rating, and then
rounding off the result.
In the previous examples, we calculated that an MX10016 AC power system requires 22800 W with 16 line cards.
In this example, we calculate the total power available for this configuration:
(25450 W) / (2700 W) = 9.42
Round up the result to 10 AC power supplies.

JNP10K-PWR-AC Power Specifications

An MX10016 router in redundant configuration can use either AC or DC power supplies; base configuration
routers are AC power only.
Table 35 on page 102
lists the power specifications for the AC power supply (JNP10K-PWR-AC) used in
an MX10016 chassis.
Table 35: Power Specifications for a JNP10K-PWR-AC Power Supply
Item
AC input voltage
AC input line frequency
AC input current rating
AC output power
Specifications
Operating range: 200–240 VAC
50–60 Hz
16 A
2700 W
102

Advertisement

Table of Contents
loading

Table of Contents