Removing An Mx10016 Router From A Four-Post Rack Using A Mechanical Lift - Juniper MX10016 Hardware Manual

Universal routing platform
Hide thumbs Also See for MX10016:
Table of Contents

Advertisement

Unmounting file systems:
init: Re-executing /sbin/init
Halting system...
System halted.
CAUTION:
the System halted.. Wait at least 60 seconds after first seeing this message before
following the instructions in Step
3. Wrap and fasten one end of an ESD strap around your bare wrist, and connect the other end of the
strap to the ESD point on the chassis.
4. To disconnect power to the router:
AC power supply—Set the enable switch to the OFF (O) position and gently pull out the coupler for
the power cord from the faceplate.
DC power supply—Switch the circuit breaker on the panel board that services the DC circuit to the
OFF position.
5. Remove the power source cable from the power supply faceplate:
AC power supply—Remove the power cord from the power supply faceplate by detaching the power
cord retainer and gently pulling out the male end of the power cord connected to the power supply
faceplate.
DC power supply—Loosen the thumbscrews securing the DC power connector on the power source
cables. Remove the power source cables from the power supply faceplate.
6. Uncable the router before removing it from the rack.
Removing an MX10016 Router From a Four-Post Rack Using a Mechanical
Lift
Because of the size and weight of the router, we strongly recommend using a mechanical lift to remove
the MX10016.
Before you remove the router using a lift:
[
OK
]
The final output of any version of the request vmhost halt command is
4
and Step
5
to power off the router.