Table 16: LEDs on an , JNP10K-PWR-AC, Power Supply in an MX10016 (continued)
LED
PWR OK
FAULT
NOTE:
If the INP1 or INP2 LED and the PWR OK LED are unlit, the AC power cord is not installed
properly or the power supply has failed.
If the INP1 or INP2 LED is lit and the PWR OK LED is unlit, the AC power supply is not installed
properly or the power supply has an internal failure.

JNP10K-PWR-AC2 Power Supply LEDs

The JNP10K-PWR-AC2 power supply has four LEDs on its faceplate: !, OK, 2, and 1. These LEDs display
information about the status of the power supply. See
Color
State
Green
On steadily
Yellow
Blinking
Unlit
Off
Red
On steadily
Description
AC power output is within normal operating range.
AC power output is out of the normal operating
range.
The power supply is functioning normally.
The power supply has failed and must be replaced.
Only one input is powered and the enable switch
for the input that is not powered is set to ON. See
"MX10016 Power System" on page 57
information about the enable switches.
Figure 30 on page
70.