Table 13: Power Supply Overview
JNP10K-PWR-AC
Maximum
2700 W
output power
Inputs
2 (INP1, INP2)
Compatible
Standard
power bus
Note:
*JNP10K-PWR-AC2 and JNP10K-PWR-DC2 models can use the standard bus. The available power is 3000 W for
power budget from the power management software.

JNP10K-PWR-AC Power Supply

The JNP10K-PWR-AC power supplies are hot-insertable, hot-removable, field-replaceable units (FRUs).
In an MX10016, you can install up to 10 power supplies in the slots labeled PSU 0 through PSU 9. You
can install the power supplies in any slot.
The JNP10K-PWR-AC power supplies are 2700-W and support 200–240 VAC. The output is 12 VDC;
the output power is 2700 W.
The AC power supply supports 200–240 VAC. The output is 12 VDC; the output power is 2700 W.
CAUTION:
can coexist in the same chassis during the hot swap of AC for HVAC. Do not mix AC and
HVAC power supplies in a running environment.
WARNING:
location. It has a separate protective earthing terminal on the chassis that must be
connected to earth ground permanently to ground the chassis adequately and protect
the operator from electrical hazards.
JNP10K-PWR-AC2
5000 W or 5500 W
when set for high power
(30-A); 3000 W when
set for low power (20-A)
2 (INP1, INP2)
Standard or enhanced*
Do not mix AC and DC power supplies in the same chassis. AC and HVAC
The router is pluggable type A equipment installed in a restricted-access
JNP10K-PWR-DC
JNP10K-PWR-DC2
2500 W
5500 W when set for
high power (80-A) or
4400 W when set for
low power (60-A)
2 (INPUT 1, INPUT
4 (INPUT 1, INPUT 2)
2)
Standard
Standard or enhanced*
58