How To Install A Jnp10K-Pwr-Dc Power Supply - Juniper MX10016 Hardware Manual

Universal routing platform
Hide thumbs Also See for MX10016:
Table of Contents

Advertisement

Figure 84: Removing a JNP10K-PWR-DC Power Supply from an MX10016
Keep latch in open position during removal.

How to Install a JNP10K-PWR-DC Power Supply

The JNP10K-PWR-DC power supply in an MX10016 chassis is a hot-removable and hot-insertable
field-replaceable unit (FRU). You can install up to 10 JNP10K-PWR-DC power supplies in an MX10016
router chassis. All DC power supplies install in the rear of the chassis in the slots along the left side of the
chassis.
Before you install a JNP10K-PWR-DC power supply in the chassis, ensure that you have followed all safety
warnings and cautions:
WARNING:
from the DC circuit. To ensure that all power is off, locate the circuit breaker on the panel
board that services the DC circuit, switch the circuit breaker to the OFF position, and
secure the handle of the circuit breaker in the OFF position using tape.
CAUTION:
a cable lug to the grounding cable and power cables that you supply. A cable with an
incorrectly attached lug can damage the router (for example, by causing a short circuit).
Before performing DC power procedures, ensure that power is removed
Before you connect power to the router, a licensed electrician must attach