The MX10016 cooling system components work together to keep all components within the acceptable
temperature range. If the maximum temperature specification is exceeded and the system cannot be
adequately cooled, the Routing and Control Board shuts down some or all of the hardware components.
For more information, see the following topics:

MX10016 Cooling System and Airflow

IN THIS SECTION
MX10016 Fan Trays | 46
MX10016 Fan Tray Controllers | 47
Airflow Direction in an MX10016 | 49
The cooling system in an MX10016 chassis consists of two fan trays and two fan tray controllers. An
MX10016 has an air filter on the front panel. The fans in each fan tray are numbered 0 through 10.
Two fan tray models and their associated fan tray controllers are available. All models are hot-insertable
and hot-removable. See
Table 9 on page
Table 9: Fan Tray Specifications
Specification
Corresponding fan tray controller
model
Chassis supported
Number of fans per fan tray
Number of fans per chassis
Volume flow at 100%
Introduced in Junos OS Release
Height
Width
45.
JNP10016-FAN
JNP10016-FAN-CTLR
Enhanced or standard
11
22
2,744.07 CFM per fan tray
15.1X53-D30
22.4 in. (56.9 cm)
6.6 in. (16.8 cm)
JNP10016-FAN2
JNP10016-FTC2
Enhanced or standard
22
44
3,423 CFM per fan tray
19.2R1
22.4 in. (56.9 cm)
6.6 in. (16.8 cm)