Mx10008 Grounding Cable And Lug Specifications - Juniper MX10008 Hardware Manual

Universal routing platform
Table of Contents

Advertisement

Table 44: Power Specifications for the JNP10K-PWR-DC2 Power Supply (continued)
Item
Specifications
Output power
2200 W for low input (60-A) single feed
4400 W for low input (60-A) dual feed
2750 W for high input (80-A) single feed
5500 W for high input (80-A) dual feed
Table 45 on page 117
shows the physical specifications for a JNP10K-PWR-DC2 power supply.
Table 45: Physical Specifications of a JNP10K-PWR-DC2 Power Supply
Specification
Height
Width
Depth
Weight

MX10008 Grounding Cable and Lug Specifications

For installations that require a separate grounding conductor to the chassis, the router must be adequately
grounded before power is connected to ensure proper operation and to meet safety and electromagnetic
interference (EMI) requirements. To ground an MX10008 chassis, connect a grounding cable to earth
ground and then attach it to the chassis grounding point on the rear of the chassis beneath.
WARNING:
location. It has a separate protective earthing terminal provided on the chassis in addition
to the grounding pin of the power supply cord. This separate protective earthing terminal
must be permanently connected to earth ground for installations that require a separate
grounding conductor to the chassis.
Value
3.5 in. (8.89 cm)
3.6 in. (9.14 cm)
16.05 in. (40.77 cm)
8.1 lbs (3.67 kg)
The router is pluggable type A equipment installed in a restricted-access