Advertisement

4. Service Tables
Address
680501
Line current detection time
680502
Line current wait time
680503
Line current drop detect time
PSTN dial tone frequency upper limit
680504
(high byte)
PSTN dial tone frequency upper limit
680505
(low byte)
PSTN dial tone frequency lower limit
680506
(high byte)
PSTN dial tone frequency lower limit
680507
(low byte)
680508
PSTN dial tone detection time
680509
PSTN dial tone reset time (LOW)
68050A
PSTN dial tone reset time (HIGH)
68050B
PSTN dial tone continuous tone time
68050C
PSTN dial tone permissible drop time
68050D
PSTN wait interval (LOW)
68050E
PSTN wait interval (HIGH)
68050F
PSTN ring-back tone detection time
680510
PSTN ring-back tone off detection time
PSTN detection time for silent period
680511
after ring-back tone detected (LOW)
PSTN detection time for silent period
680512
after ring-back tone detected (HIGH)
162
Function
Unit
Line current detection is
disabled.
20 ms
Line current is not detected if
680501 contains FF.
If both addresses contain
Hz (BCD)
FF(H), tone detection is
disabled.
If both addresses contain
Hz (BCD)
FF(H), tone detection is
disabled.
If 680508 contains FF(H),
the machine pauses for the
pause time (address
68050D / 68050E).
20 ms
Italy: See Note 2.
-
Detection is disabled if this
20 ms
contains FF.
20 ms
-
20 ms
-
20 ms
-
Remarks