Chrysler Sebring 2004 Service Manual page 1971

Table of Contents

Advertisement

DRIVEABILITY - GAS
Symptom:
P0106-BAROMETRIC PRESSURE OUT OF RANGE
When Monitored and Set Condition:
P0106-BAROMETRIC PRESSURE OUT OF RANGE
When Monitored: With the ignition key on. No Cam or Crank signal within 75 ms. Engine
speed at less than 250 RPM.
Set Condition: The PCM senses the voltage from the MAP sensor to be less than 2.196
volts but above 0.0392 volts for 300 milliseconds.
MAP SENSOR VOLTAGE BELOW 2.2 VOLTS
(K6) 5-VOLT SUPPLY CIRCUIT SHORTED TO VOLTAGE
(K6) 5-VOLT SUPPLY CIRCUIT SHORTED TO GROUND
(K6) 5-VOLT SUPPLY CIRCUIT OPEN
MAP SENSOR INTERNAL FAILURE
(K1) MAP SENSOR SIGNAL CIRCUIT OPEN
(K1) MAP SENSOR SIGNAL CIRCUIT SHORTED TO GROUND
PCM
TEST
1
Turn the ignition on. (Do not start engine)
With the DRBIII , read the MAP Sensor voltage.
Is the voltage below 2.2 volts.
Yes → Go To 2
No
2
Turn the ignition off.
Disconnect the MAP Sensor harness connector.
Turn the ignition on.
Measure the voltage of the (K6) 5-volt Supply circuit in the MAP Sensor harness
connector.
Is the voltage between 4.5 to 5.2 volts?
Yes → Go To 3
No
POSSIBLE CAUSES
ACTION
→ Refer to the INTERMITTENT CONDITION symptom in the
Driveability category.
Perform POWERTRAIN VERIFICATION TEST VER - 5.
→ Go To 6
42
APPLICABILITY
All
All

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sebring convertible 2004Stratus 2004

Table of Contents