Figure 105: Sla Example - Sla Station; Figure 106: Sla Example - Mpk Configuration - Grandstream Networks UCM6100 Series User Manual

Ip pbx
Hide thumbs Also See for UCM6100 Series:
Table of Contents

Advertisement

4. On the SIP phone 1, configure to register UCM6100 extension 1002. Configure the MPK as BLF mode and
the value must be set to "extension_trunkname", which is 1002_fxo1 in this case.
5. On the SIP phone 2, configure to register UCM6100 extension 1005. Configure the MPK as BLF mode and
value must be set to "extension_trunkname", which is 1005_fxo1 in this case.
Now the SLA station is ready to use. The following functions can be achieved by this configuration.
Making an outbound call from the station/extension, using LINE key
When the extension is in idle state, pressing the line key for this extension on the phone to off hook. Then
dial the station's extension number, for example, dial 1002 on phone 1 (or dial 1005 on phone 2), to hear the
dial tone. Then the users could dial external number for the outbound call.
Making an outbound call from the station/extension, using BLF key
When the extension is in idle state, pressing the MPK and users could dial external numbers directly.
Answering call using LINE key
When the station is ringing, pressing the LINE key to answer the incoming call.
Barging-in active call using BLF key
When there is an active call between an SLA station and an external number using the SLA trunk, other SLA
stations monitoring the same trunk could join the call by pressing the BLF key if "Barge Allowed" is enabled
for the analog trunk.
Hold/UnHold using BLF key
If the external line is previously put on hold by an SLA station, another station that monitors the same SLA
trunk could UnHold the call by pressing the BLF key if "Hold Access" is set to "open" on the analog trunk and
the SLA station.

Figure 105: SLA Example - SLA Station

Figure 106: SLA Example - MPK Configuration

UCM6100 Series User Manual
Version 1.0.18.13
P a g e
|
197

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ucm6102Ucm6104Ucm6108Ucm6116

Table of Contents