Concurrent
The maximum endpoints which can be registered into this extension. For security
Registrations
concerns, the default value is 1.
Other Settings
Enable SRTP for the call.
SRTP
The default setting is "No".
Select Fax mode for this user. The default setting is "None".
Fax Mode
This option controls how the extension can be used on devices within different types
of network. The default setting is "Allow All".
Strategy
Enable T.38
Enable or disable T.38 UDPTL Support.
UDPTL
If enable "All", users do not need to enter password when making an outbound call. If
Skip Trunk Auth
enable "Follow Me", the user can dial out via follow me without password.
Select audio and video codec for the extension. The available codecs are: PCMU,
Codec Preference
PCMA, GSM, AAL2-G.726-32, G.722, G.729, G.723, iLBC, ADPCM, LPC10, H.264,
H.265, H.263, H.263p and VP8.

Batch Add IAX Extensions

Under Web GUI→Extension/Trunk→Extensions, click on "Add", then select extension type as IAX Extension
and the add method to be Batch.
General
Start Extension
Configure the starting extension number of the batch of extensions to be added.
Create Number
Specify the number of extensions to be added. The default setting is 5.
None: Disable Fax.
Fax Detect: Fax signal from the user/trunk during the call can be detected and
the received Fax will be sent to the Email address configured for this extension.
If no Email address can be found for the user, the Fax will be sent to the default
Email address configured in Fax setting page under Web GUI→Call
Features→Fax/T.38.
Allow All
Device in any network can register this extension.
Local Subnet Only
Only the user in specific subnet can register this extension. Up to three subnet
addresses can be specified.
A Specific IP Address
Only the device on the specific IP address can register this extension.

Table 47: Batch Add IAX Extension Parameters