Installing/mounting

4.2 Installation instructions

4.2
Installation instructions
NOTICE
Damage to the flange
If mating flange faces are not flat and free of distortion, then bolting the flanged process
connection may produce a bending load on the device's flange. Cracking or other damage
may occur.
Use only 'full-face' flat gaskets surrounding the bolt holes. Ensure mating flange faces are
flat and free of distortion.
4.2.1

Pressure equipment directive (PED, 2014/68/EU)

Note
Pressure-rated version only
• SITRANS LR560 units are pressure tested, meeting or exceeding the requirements of the
ASME Boiler and Pressure Vessel Code and the European Pressure Equipment
Directive.
• The serial numbers stamped in each process connection body provide a unique
identification number indicating date of manufacture.
Example: MMDDYY – XXX (where MM = month, DD = day, YY = year, and XXX=
sequential unit produced)
• Further markings (space permitting) indicate flange configuration, size, pressure class,
material, and material heat code.
SITRANS LR560 radar level measurement instrument falls below the limits of Article 4, sections
1&2 of the Pressure Equipment directive (2014/68/EU), as a category I pressure accessory.
However, in accordance with PED, 2014/68/EU, Article 4, section 3, this equipment has been
designed and manufactured in accordance with Sound Engineering Practice (SEP) (see EU
Commission Guideline A-05).
26
SITRANS LR560 (mA/HART)
Operating Instructions, 06/2017, A5E34647946-AD