Parameter Reference
8.2 SETUP (2.)
8.2.2.3

DAMPING FILTER (2.2.3.)

Note
Response rate
For time constant values corresponding to response rate settings, please see RESPONSE
RATE (2.4.1.) (Page 114).
Factory setting:
Setting range:
Purpose:
8.2.2.4

TEMPERATURE UNITS (2.2.4.)

Factory setting:
Setting range:
Purpose:
112
Level
sensor reference point
20 mA, 100%
low calibration point
60 s
0 to 1500 s
The time constant for the damping filter. The damping filter smooths out the
response to a sudden change in level. This is an exponential filter and the
engineering unit is always in seconds (see Damping (Page 187) for more
detail).
Degrees C
Degrees C, F, R, or K
Selects the engineering unit to be displayed with the value representing
temperature.
Space
high calibration point
4 mA, 0%
Operating Instructions, 06/2017, A5E34647946-AD
Distance
SITRANS LR560 (mA/HART)