Technical data

11.3 Construction

11.3
Construction
Process connection:
Enclosure
Lens antenna
material
Air purge connection
Weight (excluding
extensions):
Universal flange mates with EN 1092-1 (PN16)/ASME B16.5 (150 lb)/JIS 2220 (10K) bolt hole
1)
pattern.
11.4

Operating conditions

Note
• For the specific configuration you are about to use or install, check transmitter nameplate
and see Approvals data (Page 165).
• Use appropriate conduit seals to maintain IP or NEMA rating.
Location
Altitude
Ambient temperature
Storage temperature
Relative humidity
Installation category
Pollution degree
164
Universal flat-faced flange
1)
Aimer flange
1)
Universal stamped
flange
1)
Construction
Conduit entry
Conduit entry connector
(optional)
Ingress protection
Lid with window
Sun shield (optional)
40 m version
100 m version
equipped with female 1/8" NPT fitting
3" stainless steel flange
model
indoor/outdoor
5000 m (16,404 ft) max.
−40 to +80 °C (−40 to +176 °F)
−40 to +80 °C (−40 to +176 °F)
suitable for outdoor use
Type 4X/NEMA 4X, Type 6/NEMA 6, IP68 enclosure (see
note above)
I
4
3"/80 mm, 4"/100 mm, 6"/150 mm
Material: 316L (1.4404 or 1.4435), or 304
stainless steel
3"/80 mm, 4"/100 mm, 6"/150 mm
Material: Polyurethane powder-coated cast
aluminum
3"/80 mm, 4"/100 mm, 6"/150 mm
Material: 304 stainless steel
316L/1.4404 stainless steel
M20x1.5, or ½" NPT
M12 connector (shipped with M20 to M12
adaptor) or,
7/8" connector (shipped with 1/2" NPT to
7/8" adaptor)
Type 4X/NEMA 4X, Type 6/NEMA 6, IP68
Polycarbonate (window material)
304 stainless steel
PEI
PEEK
3.15 kg (6.94 lb)
SITRANS LR560 (mA/HART)
Operating Instructions, 06/2017, A5E34647946-AD