8.2.1.9
MENU TIMEOUT (2.1.9.)
Factory setting:
Setting range:
Purpose:
8.2.1.10
MANUFACTURE DATE (2.1.10.)
The date of manufacture of the device (dd mm yyyy).
8.2.2
SENSOR (2.2.)
8.2.2.1
UNITS (2.2.1.)
Factory setting:
Setting range:
Purpose:
Description:
8.2.2.2
SENSOR MODE (2.2.2.)
Factory setting:
Setting range:
Purpose:
Description:
SITRANS LR560 (mA/HART)
Operating Instructions, 06/2017, A5E34647946-AD
120 s
15 to 65535 s
Time menu stays visible before switching back to Measurement view if no
key is pressed.
m
m, cm, mm, ft, in, %
PV (Primary Value) and SV (Secondary Sensor measurement units). Used
in setting High/Low Calibration Point, and displayed on LCD and in PDM.
Changing units to % will update the mA setpoints.
DISTANCE
LEVEL, SPACE, DISTANCE
Distance to material surface
LEVEL
Low Calibration Point (process empty level)
SPACE
High Calibration Point (process full level)
DISTANCE
Sensor Reference Point
Parameter Reference