Vessel
Factory setting:
Setting range:
Purpose:
Description:
Response rate
Factory setting:
Setting range:
Purpose:
Description:
SITRANS LR560 (mA/HART)
Operating Instructions, 06/2017, A5E34647946-AD
STEEL
STEEL or CONCRETE
Select vessel construction material.
Selecting either STEEL or CONCRETE does a functional reset; see
MASTER RESET (4.2.) (Page 138).
Selecting STEEL changes the setting for POSITION DETECT (2.7.3.3)
(Page 122) to Rising Edge and for ALGORITHM (2.7.3.1) (Page 122) to
F.
Selecting CONCRETE changes the setting for POSITION DETECT
(2.7.3.3) (Page 122) to Rising Edge and for ALGORITHM (2.7.3.1)
(Page 122) to ALF.
Parameter view
MED
Response rate Fill rate per Minute/Empty rate per
SLOW
MED
FAST
Sets the reaction speed of the device to measurement changes in the
target range. Selecting SLOW changes setting for AVERAGE AMOUNT
(2.7.5.3.) (Page 126) to 0.9.
Use a setting just faster than the maximum vessel filling or vessel empty-
ing rate (whichever is greater).
Parameter view
6.5 Commissioning via handheld programmer
Minute
0.1 m/min (0.32 ft/min)
1.0 m/min (3.28 ft/min)
10.0 m/min (32.8 ft/min)
Commissioning
Edit mode
Damping Filter
600 s
60 s
0 s
Edit mode