Siemens SITRANS LR560 Operating Instructions Manual page 80

Radar transmitters ma/hart
Hide thumbs Also See for SITRANS LR560:
Table of Contents

Advertisement

Configuring a new device
1. Check our website to make sure you have the most recent EDD.
website (www.siemens.com/LR560)
Go to Support > Software Downloads and if necessary download it. Save the files to your
computer, and extract the zipped file to an easily accessed location.
2. Launch AMS Device Manager– Add Device Type, browse to the unzipped EDD file and select
it.
Startup
1. Launch AMS Device Manager. (Application Guides for setting up HART devices with AMS
Device Manager can be downloaded from our website:
website (www.siemens.com/LR560)
2. In Device Connection View right-click on the device icon and select Scan Device to upload
parameters from the device.
3. Double click the device icon to open the startup screen. The startup screen shows device
identification details and a navigation window on the left side of the screen.
Master reset
Note
Device Address (5.1.) remains unchanged if the reset command is sent remotely (via AMS,
PDM, DTM, FC375) but is reset to 0 if the reset command is sent via LUI.
● Navigate to Configure/Setup > Operation
● In the General field click on Master Reset and accept the option Factory Defaults.
SITRANS LR560 (mA/HART)
Operating Instructions, 06/2017, A5E34647946-AD
Operating
7.1 Remote operation
79