Installation - Control Module

APPLICATION 1: AUTO/MANUAL CONTROL

Ideal for automatic control applications with limit switches or proximity transducers
MANUAL SETPOINT
AUTO SETPOINT
MANUAL RUN
AUTO RUN
AUTO SELECT
REVERSE
NOT COAST STOP
NOT QUICKSTOP
TRIP RESET
Auto/Manual Control Application
Two Run inputs and two Setpoint inputs are provided. The Auto/Manual switch selects which pair of inputs is active.
The Application is sometimes referred to as Local/Remote.
ANIN 01 (X11/01)
ANIN 02 (X11/02)
REF SELECT
DIGIN 01 (X13/02)
DIGIN 02 (X13/03)
RUN SELECT
DIGIN 03 (X13/04)
DIGIN 04 (X12/01)
DIGIN 05 (X12/02)
DIGIN 06 (X12/03)
DIGIN 07 (X12/02)
SEQUENCING LOGIC
0484
Application 1:
"Auto/Manual Control"
IDEAL FOR AUTOMATIC CONTROL
APPLICATIONS WITH LIMIT SWITCHES OR
PROXIMITY TRANSDUCERS
Ref Max Speed Clamp
1265
FWD / REV
MIN /MAX SPEED
Ref Min Speed Clamp
1264
F
V
V/F SHAPING
I FDBK
Vhz Shape
0422
Base Frequency
0457
Fixed Boost
0447
Seq Stop Method
Acceleration Time
0486
RAMP
Deceleration Time
0487
Stop Ramp Time
0504
Quickstop Ramp Time
0508
F
V
CURRENT LIMIT
PWM CONTROL
ANOUT 01 (X11/03)
Rated Motor Current
0455
ANOUT 02 (X11/04)
FEEDBACKS
RELAY 01
if AC30V
OR
RELAY 11
Requires IO Option
7004-01-00
RELAY 02
if AC30V
OR
RELAY 12
Requires IO Option
7004-01-00
AC30 series Variable Speed Inverter
SPEED DEMAND
MOTOR CURRENT
(X14/01)
(X14/02)
RUNNING
(X23/01)
(X23/02)
(X14/03)
(X14/04)
NOT
(X23/03)