Chapter 10: Routine Maintenance & Repair; Routine Maintenance; Preventative Maintenance; Main Duct Fans - Parker AC30P Hardware Installation Manual

Variable speed drive
Hide thumbs Also See for AC30P:
Table of Contents

Advertisement

Routine Maintenance & Repair
Chapter 10:

Routine Maintenance

Periodically inspect the inverter for build-up of dust or obstructions that may affect ventilation of the unit. Remove this using dry air.

Preventative Maintenance

MAIN DUCT FANS

For preventative maintenance, replace the fans every 5 years of operation, or whenever the inverter trips on 'heatsink overtemperature' under
normal operation. The unit must be returned to your local Parker Service Center for fan replacement.

DC LINK CAPACITORS

For preventative maintenance the DC link capacitors must be replaced every 10 years operation, or when the inverter trips on 'DC link ripple'
under normal operating conditions. The unit must be returned to your local Parker sales office for replacement.

Repair

There are no user-serviceable components. Only Parker trained personnel are permitted to repair this product to maintain certifications, reliability
and quality levels.
MAKE NO ATTEMPT TO REPAIR THE UNIT - RETURN IT TO PARKER

SAVING YOUR APPLICATION DATA

In the event of a repair, application data will be saved whenever possible. However, we advise you to backup your application settings before
returning the unit.

RETURNING THE UNIT TO PARKER

Please have the following information available:
The model and serial number - see the unit's rating label
Detailed information on the nature of the fault as well as a full description of the application and history. This is important to ensure
Parker can diagnose to root cause before return.
Contact your nearest please contact your local Parker Service Center to arrange return of the item and to be given a Authorisation To Return
(ATR) number. Use this as a reference on all paperwork you return with the faulty item. Pack and despatch the item in the original packing
materials; or at least an anti-static enclosure. Do not allow packaging chips to enter the unit. Please include the fault information described above.
Routine Maintenance & Repair
AC30 series Variable Speed Inverter
10-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ac30 seriesAc30vAc30d

Table of Contents