Safety Details; Analog Inputs/Outputs - Parker AC30P Hardware Installation Manual

Variable speed drive
Hide thumbs Also See for AC30P:
Table of Contents

Advertisement

F-2
Technical Specifications - Control Module

SAFETY DETAILS

Overvoltage Category
Pollution Degree
North America/Canada

ANALOG INPUTS/OUTPUTS

AIN1 (X11/01), AIN2 (X11/02), AOUT1 (X11/03), AOUT2 (X11/04)
Conforming to EN61131-2
Range
Impedance
Resolution
Accuracy
Sample / Update Rate
AC30 series Variable Speed Drive
Overvoltage Category III (numeral defining an impulse withstand level)
Pollution Degree II (non-conductive pollution, except for temporary condensation) for control electronics
Pollution Degree III (dirty air rating) for through-panel mounted parts
Complies with the requirements of UL508C as an open-type drive.
Inputs
AIN1:
Range selected by parameter 0001 from:
0 to 10V, -10V to +10V, 0 to 20mA, 4 to 20mA
AIN2:
Range selected by parameter 0002 from:
0 to 10V, -10V to +10V
Absolute maximum input current 25mA in current mode
(AIN1 only)
Absolute maximum input voltage ±24V dc in voltage mode
Input impedance:
Voltage range = 22kΩ
Current range = 120R
12 bits (1 in 4096) over full range
Better than ±1%
1ms
Output
AOUT1:
Range selected by parameter 0003 from:
0 to 10V, -10V to +10V
AOUT2:
Range selected by parameter 0004 from:
0 to 10V, 0 to 20mA, 4 to 20mA
Maximum rated output current in voltage mode
10mA, with short circuit protection
Load impedance :
Voltage range ≥ 1kΩ
Current range ≤ 600Ω
11 bits (1 in 2048)
Better than ±1%
1ms

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ac30 seriesAc30vAc30d

Table of Contents