Ac Line Fed Power Stack - Y-Cap & Vdr Disconnects - Parker AC30P Hardware Installation Manual

Variable speed drive
Hide thumbs Also See for AC30P:
Table of Contents

Advertisement

4-15
Installation - Power Stack
AC
LINE FED POWER STACK – Y-CAP & VDR DISCONNECTS
With the front panel removed, links CN1 and CN2 are accessible on the AC line filter PCB. Each link can be removed independently to
disconnect either the Y-capacitors from earth (CN1) or the VDRs (line voltage suppressors) from earth (CN2).
It may be required to do this in system applications where there are RCD's in circuit or where the inverter is installed on an IT supply:
WARNING
Disconnection of the EMC filter invalidates the CE EMC Declaration. The product becomes a component for incorporation and the
conformity of the complete equipment or installation becomes the responsibility of the installer.
Refer to 'Appendix A: Compliance' for more information on conducted emissions EMC compliance.
CN1
CN2
Note: When links are fitted they should be across pins
1 and 4 on the connectors, as shown above.
AC30 series Variable Speed Inverter

Advertisement