Sd Frame E Power Connections - Parker 890SD Quick Start Manual

Standalone drive
Hide thumbs Also See for 890SD:
Table of Contents

Advertisement

890SD Frame E Power Connections

5
Connect motor leads to M1/U, M2/V, M3/W.
Maximum wire sizes::
Frame E:
50mm
70mm
Connect the earth/ground wire from the terminal
box of the motor directly to the earth/ground
terminal.
Maximum wire sizes:
Frame E:
50mm
70mm
If not using shielded cable, run motor leads in an
enclosed metal conduit bonded to the drive at
one end and the motor at the other.
6
Connect the earth/ground wire to the
earth/ground terminal.
Maximum wire sizes:
Frame E:
50mm
70mm
PE1
6
5
All screens terminated using
a gland at the gland plate
2
/1AWG (without crimp)
2
/ 1/0AWG (with crimp)
2
/1AWG (without crimp)
2
/ 1/0AWG (with crimp)
2
/1AWG (without crimp)
2
/ 1/0AWG (with crimp)
6
7
3-Phase Supply
7
Connect the 3-phase supply.
Maximum wire sizes:
Frame E:
50mm
70mm
8
Connect the brake resistor.
Maximum wire sizes:
Frame E:
50mm
70mm
An External Braking Resistor is optional.
Connect it between DBR+ and DBR- for
high inertial loads.
DO NOT apply external voltage sources
(mains supply or otherwise) to the braking
terminals.
We recommend using a thermal overload
switch to protect the braking circuit.
Motor
5
2
/1AWG (without crimp)
2
/ 1/0AWG (with crimp)
2
/1AWG (without crimp)
2
/ 1/0AWG (with crimp)
Brake
Resistor
8
Page 11

Advertisement

Table of Contents
loading

This manual is also suitable for: