Built-in Positioning Functions
10. Variable Speed Operation
(Variable Speed Pulse Output)-PLSV Instruction
The built-in positioning function uses the variable speed pulse output (PLSV) instruction equipped with the
rotation direction designation function to perform variable speed operation. If an FX
later or FX
PLC is used, this instruction can change the speed using the acceleration/deceleration speed.
3G
10.1

Instruction Format

1. Instruction Format
FNC 157
D
PLSV
PULSE V
2. Data setting
Operand type
S
D
1
D
2
*1.
Setting range : -32,768 Hz to -1 Hz and +1 Hz to 32,767 Hz for 16-bit operation. For the
3. Devices
Operand
System user
type
X Y M T C S D .b KnX KnY KnM KnS T C D R
S
D
1
1
D
2
2
1 : Specify Y000, Y001, or Y002
*3
Y003
from a high-speed output special adapter
*1.
Y002 is not available in 14-point and 24-point type
*2.
High-speed input/output special adapters can be connected only to the
*3.
To use Y002 and Y003 with a high-speed output special adapter, connect a second high-speed output
special adapter.
B - 132
→ For the items to be observed in programming, refer to Section 4.7.
16-bit
Instruction
instruction
symbol
PLSV
9 steps
-
Specifies the output pulse frequency designation device number.
Specifies the pulse output device number.
Specifies the rotation direction signal output destination device number.
32-bit operation, however, the setting range should be as shown in the following table.
Pulse output destination
FX
PLC
3U
FX
/FX
/FX
3G
3U
3UC
PLC
Bit device
Digit designation
3
*1
transistor output from the main unit, or specify Y000, Y001, Y002

10 Variable Speed Operation (Variable Speed Pulse Output)-PLSV Instruction

Execution condition
instruction
Continuous
17 steps
execution
type
Description
High-speed output special adapter -200,000 to -1 to +1 to 200,000(Hz)
Main unit (transistor output)
Word device
System
Special
user
unit
U \G
4
*2
.
PLC.
FX
3G
10.1 Instruction Format
FX
PLC Ver.2.20 or
3U/
3UC
32-bit
Instruction
Execution condition
symbol
DPLSV
-
*1
Setting range
-100,000 to -1 to +1 to 100,000(Hz)
Others
Real
Con-
Index
num-
stant
ber
V Z Modify K
H
E
PLC.
FX
3U
Continuous
execution
type
Data type
BIN 16/32-bit
Bit
Char-
acter
Pointer
string
" "
P
*3
, or

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3u seriesFx3uc seriesFx3u-2hsy-adp

Table of Contents