Example Connection
2. FX
PLC
3UC
FX
-32MT/D
3UC
Photo-
coupler
COM
X000
X004
X010
DOG
X014
X017
COM1
COM1
Y000
Y004
Y017
FX
-16EYT
2NC
COM1
COM1
Y020
Y27
FX
-16EX
2NC
Photo-
coupler
COM
X020
X021
X022
X023
X024
X025
X026
X027
X030
X037
Be sure to use the class-D grounding method (grounding resistance: 100 Ω or less).
*1.
*2.
Near-point signal (DOG)
*3.
Set the servo amplifier parameter No.21 to "020".
*4.
To ensure safety, use the forward rotation limit switch and the reverse rotation limit switch on both sides: the PLC side and
the servo amplifier side. Note that the limit switches on the PLC side should be activated slightly earlier than the limit
switches on the servo amplifier side.
Reverse rotation limit 2
(Servo amplifier side)
Servo motor
24V DC
Class-D
grounding
*1
Zero Point
signal(PG0)
Servo ready
(RD)
*2
Pulse train
Direction
CLEAR signal
Immediate stop command
Zero return command
JOG(+)command
JOG(-)command
Forward rotation positioning command
Reverse rotation positioning command
Forward rotation limit (LSF)
Reverse rotation limit (LSR)
Stop command
Reverse rotation limit 1
(Programmable
controller side)
LSR
Reverse rotation
Appendix 4. MELSERVO-C Series
Appendix 4-1 Main Unit (Transistor Output)
MR-C A
Series servo
amplifier
CN1
OP
4
*3
RD
3
CN1
12
SG
20
V24
SG
5
19
OPC
PP
9
1
V+
NP
7
2
ALM
14
LSN
15
LSP
17
SON
CR
13
SD
11
*4
*4
Forward rotation limit 1
Forward rotation limit 2
(Programmable
controller side)
LSF
Forward rotation
Servo error(ALM)
Forward rotation limit 2
Reverse rotation limit 2
Servo ON
(Servo amplifier side)
Apx. - 19
A
B
Apx.
*4
*4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3u seriesFx3uc seriesFx3u-2hsy-adp

Table of Contents