Assignment of Output Numbers

FX
/FX
/FX
1.
3G
3U
Application
Pulse train signal
(Pulse output
destination)
Direction signal
(Rotational
direction signal)
CLEAR signal
*1.
Y002 (pulse output destination) cannot be specified when the 14-point or 24-point type FX
connected.
*2.
Specify an output number for transistor output.
-16M , FX
3U
3UC
PLC (main unit).
3G
PLC.
3U
Series main unit (transistor output)
3UC
Output
number
Y000
Connect a line to the output (Y000 - Y002) specified for the pulse output
Y001
designation (this output is specified by the positioning instruction).
*1
Y002
Connect a line to any output.
All output
Connect a line to the output specified for the rotation direction signal (this signal is
*2
points
specified by the positioning instruction).
Connect a line if it is necessary to use DSZR/ZRN instruction to output the CLEAR
signal.
The CLEAR signal output depends on the pulse output destination specified by
the DSZR/ZRN instruction. If the PLC version is later than the following number,
the CLEAR signal can be specified.
Pulse output destination
Y000
Y001
Y002
FX
/FX
3U
If the CLEAR signal device specification function is used, the
All output
CLEAR signal device specification register can specify an
*2
points
output for each pulse output destination.
→ For details on the CLEAR signal device specification method, refer to
The CLEAR signal device specification register depends on the pulse output
destination as shown in the following table:
Pulse output destination
1.5 Assignment of Input/Output Numbers
-16M .
and FX
PLC.
3U
3UC
PLC.
3U
Remarks
CLEAR signal
*1
PLC (transistor output) Ver. 2.20 or later:
3UC
CLEAR signal device specification register
Y000
Y001
Y002
3G
Y004
Y005
Y006
Subsection 4.3.4.
D8464
D8465
D8466
3G
1 Outline
A
B
PLC is
Apx.
PLC is
B - 11