Completion Of Instruction Execution ("Instruction Execution Complete" Flag, "Instruction Execution Abnormal End" Flag; Pulse Output Monitor" (Busy/Ready) Flag; Positioning Instruction Activation" Flag - Mitsubishi FX3G Series User Manual

Melsec-f, positioning control edition, main unit/sink output/source output, line driver output
Hide thumbs Also See for FX3G Series:
Table of Contents

Advertisement

FX
/FX
/FX
PLC User's Manual - Positioning Control Edition
3G
3U
3UC
Built-in Positioning Functions
4.4.2
Completion of Instruction Execution ("Instruction execution complete" Flag,
"Instruction execution abnormal end" Flag)
Use the "Instruction execution complete" flag or "Instruction execution abnormal end" flag to check whether
execution of the positioning instruction has been completed properly.
The "Instruction execution complete" flag and "Instruction execution abnormal end" flag are turned on or off
after each instruction. Use these flags just after the execution of each instruction.
• "Instruction execution complete" flag: Will be turned on if the instruction is executed properly.
• "Instruction execution abnormal end" flag: Will be turned on if the instruction is not executed properly.
Caution:
If the "Instruction execution complete" flag or "Instruction execution abnormal end" flag is turned on, then the
execution of the instruction (pulse outputting operation, etc.) is complete. However, it is not certain whether
the servo motor has stopped or not. Check the "positioning completion" signal of the servo amplifier (drive
unit) to determine whether the servo motor has stopped.
4.4.3

"Pulse Output Monitor" (BUSY/READY) Flag

Use the "pulse output monitor" (BUSY/READY) flag to check whether pulses are being output to the pulse
output destination device. The following table shows the "pulse output monitor" (BUSY/READY) flag of each
pulse output destination device.
Pulse output
destination device
Y000
Y001
*1
Y002
*2
Y003
*1.
Y002 (pulse output destination) cannot be specified when the 14-point or 24-point type FX
connected.
*2.
Devices related to Y003 (pulse output destination) are only valid if two FX
connected to the FX
4.4.4

"Positioning Instruction Activation" Flag

Use the "positioning instruction activation" flag of each pulse output destination device to check whether or
not a positioning instruction is being executed for the pulse output destination device. Use this flag to prevent
simultaneous activation of two or more positioning instructions for the same pulse output destination device.
Pulse output
destination device
Y000
Y001
*1
Y002
*2
Y003
*1.
Y002 (pulse output destination) cannot be specified when the 14-point or 24-point type FX
connected.
*2.
Devices related to Y003 (pulse output destination) are only valid if two FX
connected to the FX
→ For programming details, refer to Subsection 4.7.4.
"Pulse output monitor"
(BUSY/READY) flag
M8340
M8350
M8360
M8370
PLC.
3U
"Positioning instruction
Activation" flag
M8348
ON: The positioning instruction is being activated for the
M8358
M8368
OFF: The positioning instruction is not being activated for the
M8378
PLC.
3U
4.4 Current Value and Flag for Monitoring of Operation
Status of flag and pulse
Outputting pulse (BUSY):Flag = ON
Pulse outputting stopped (READY):Flag = OFF
-2HSY-ADP adapters are
3U
Status of flag and pulse
corresponding pulse output destination.
(Even after instruction execution is completed, if the
instruction is still being activated, the flag will not be
turned off.)
corresponding pulse output destination.
-2HSY-ADP adapters are
3U
4 Before Programming
A
B
Apx.
PLC is
3G
PLC is
3G
B - 55