Change In Logic Of Interrupt Input Signal (Dvit Instruction - Mitsubishi FX3G Series User Manual

Melsec-f, positioning control edition, main unit/sink output/source output, line driver output
Hide thumbs Also See for FX3G Series:
Table of Contents

Advertisement

FX
/FX
/FX
PLC User's Manual - Positioning Control Edition
3G
3U
3UC
Built-in Positioning Functions
*1.
A device can only be specified if an FX
When using an FX
(DVIT) instruction turns ON, an operation error (error code: K6763) will occur, and the instruction will
not cause any operation.
*2.
Devices related to Y003 (pulse output destination) are only valid if two FX
connected to the FX
*3.
After setting a number in the range of 9 to E for the interrupt input signal, if the corresponding interrupt
positioning (DVIT) instruction turns ON, an operation error (error code: K6763) will occur, and the
instruction will not cause any operation.
Example program:
The following program specifies the interrupt input signal for each pulse output destination device as shown in
the following table.
Pulse output
destination device
Y000
Y001
Y002
*1
Y003
*1.
Devices related to Y003 (pulse output destination) are only valid if two FX
connected to the FX
4.3.8

Change in Logic of interrupt input Signal (DVIT Instruction)

Turn the "Interrupt signal logic reverse" relay ON or OFF to specify the logic of the interrupt input signal of the
interrupt positioning (DVIT) instruction.
Pulse output
destination device
Y000
Y001
Y002
*1
Y003
*1.
Devices related to Y003 (pulse output destination) are only valid if two FX
connected to the FX
Caution:
If a user interrupt input command (M8460 to M8463) is specified in the interrupt input signal, the logic of the
user interrupt input command cannot be specified. This is because turning on the user interrupt input
command will turn on the interrupt input signal.
B - 52
3U
PLC below Ver. 2.20, if "8" is set and then the specified interrupt positioning
3UC
PLC.
3U
Interrupt input
Setting value
signal
X003
3
M8461
8
Unused
F
Unused
F
PLC.
3U
→ For details on the interrupt input signal designation method, refer to
"Interrupt signal logic
reverse" relay
M8347
M8357
M8367
M8377
PLC.
3U
4.3 Various Special Relays for Operation Commands
/FX
PLC Ver. 2.20 or later is used.
3UC
M8000
RUN monitor
→ For operation of DVIT instruction, refer to Chapter 9.
OFF: Positive logic (Turning the input ON will turn on the
interrupt input signal.)
ON: Negative logic (Turning the input OFF will turn on the
interrupt input signal.)
4 Before Programming
-2HSY-ADP adapters are
3U
FNC 12
HFF83
MOVP
-2HSY-ADP adapters are
3U
Subsection 4.3.7.
Description
-2HSY-ADP adapters are
3U
D8336
M8336